We have installed Honeywell NStar software package on several sites using NS2 panels. Software runs great on stand alone PCs that are not on a LAN. On PCs that are on our State network the SQL server program seems to become corrupted over time (usually a few months). Has anyone experienced this and figured out exactly what is the cause? Honeywell has suggested it might by be the virus protection. Thanks,ncdoc: Please PM me and we can take from there. The solutions may vary on the problems encountered.
Download Center. Access to Honeywell's Download Center, which contains software, firmware, service packs and other downloadable files is for authorized Honeywell security dealers and distributors only. GO TO Download Center Login. The Honeywell Access Systems' NStar™ is an access control system designed to provide a. NStar software is a comprehensive access control application designed for use with the NS2 controller. NStar provides fast installation and setup with Quick Start Configuration Wizards and simple. Downloads of users and events.
I'd much prefer to treat the causes rather than the symptoms. Enjoy the day, Bill. Honeywell NStar Access Software NCDOC, The problem you described is not a known issue. The Honeywell technical support team would like to work with your installer in resolving the issue. Below are some of the questions that would be asked: 1) What Build of NStar?
2) Is MSDE7, SLQ7, MSDE2000, or SQL2000 installed? 3) 'SQL server is corrupted over time' What are the symptoms or what doesn't function? Does it indicate anything in the Windows Event or Application Views?
If this is Full SQL does it indicate anything in the SQL Logs? 4) What is done to resolve the issue? 5) What Operating System and Service Pack is installed? 6) Check PC Specifications Hard Drive Space, RAM, etc. Contact information. Thanks for the responses. We are the installer and all of these systems are installed on a variety of Dell or HP computers that are 2 years old or less.
Honeywell Nstar Software Download
They normally have a P4 1.66Ghz processor with 256Mb or 512Mb ram. OS is Win XP SP2 and the Nstar build is 19 although we recently upgraded a build 19 to the new build 45 to try and correct this problem.
However we do not know if this is a long term fix. We have contacted HAS in the past and it seems that something occurred on the PC and the Nstar program could not access it's database. HAS seemed to be aware of the type of problem and always recommended a rigorous uninstall followed by a re-install.
The then advised to remove the computer from the network. All computers on the network have the same image installed and we thought there was something in this image that was causing a conflict. Thought someone out there may have experienced the same problem. All systems on computers not connected to the LAN/WAN without this image work fine. We will contact HAS again as soon as we can get to a problem site to try and work this out.
. NS2 Configuration Guide Contents Specifications Description.1 Power Specifications. NS2 Configuration Guide Honeywell Access Systems Reader Wiring Supervised Input Wiring Each reader port supports a single 12-volt reader with Wiegand output format. Reader 1 Terminal Wire Color Wiegrand Reader TB3-1 Brown LED Control TB3-2 Green Data 0 Signal TB3-3. Honeywell Access Systems NS2 Configuration Guide Outputs Relay 1 is defaulted to control the Door 1 lock & Relay 2 is defaulted for the Door 2 lock. Relay 3 & 4 are used as auxiliary Four form-C relays SPDT (Single Poll Double Throw) gold- relays for signaling other devices.
NS2 Configuration Guide Honeywell Access Systems Enclosure Specifications Mounting One NS2 panel in a standard 19-inch, high density enclosure. Up to eight NS2 panels in a single 19-inch rack mountable enclosure Dimensions Board 9-inch Length x 5.5-inch Wide x 1-inch High Enclosure 12.5-inch Wide x 14.5-inch High x 3.5-inch Deep.
Honeywell Access Systems NS2 Configuration Guide DIP Switch Settings S10 SELECTION OFF OFF OFF OFF OFF Address 0 OFF OFF OFF OFF Address 1(default) OFF OFF OFF Address 2 OFF OFF OFF Address 3 OFF OFF OFF OFF Address 4. NS2 Configuration Guide Honeywell Access Systems Connection Schematic RESERVED RESERVED RESERVED RESERVED BROWN GREEN DATA 0 WHITE DATA 1 BLACK COMMON +12VDC SYSTEM STATUS VARIES RDR TMPR/AUX 5 LEDS BROWN DATA 0 GREEN DATA 1 WHITE OPTIONAL BLACK COMMON ETHERNET.
Honeywell Access Systems NS2 Configuration Guide Configuration Diagrams RS-232 Connection One NS2 panel for each COM port. CBL50 (RS-232) 50 ft. COM 1 COM 2 NStar Server CBL50 DIP Switch Settings (RS-232) 50 ft. S1-S5: Panel Address S6: OFF (RS-485 Disable). NS2 Configuration Guide Honeywell Access Systems RS-485 Connection Thirty-one NS2 panels for each drop line. COM Port RS-232 (50 Ft.
Max.) RS-485 (4,000 Ft.) N-485-PCI-2 Refer to 485-PCI / NS2 Panel NStar Server Connection Detail diagram. DIP Switch Settings RS-485 Cable.
Honeywell Access Systems NS2 Configuration Guide NSLAN1 Connection One NSLAN1 for each NS2 panel, Maximum sixty-four IP connections. 100BaseT (CAT 5) 328 Ft. NStar Server Panel NSLAN1 installed 100BaseT (CAT 5) 328 Ft. DIP Switch Settings NSLAN1 must be. NS2 Configuration Guide Honeywell Access Systems LANSRL100 Connection Thirty-one NS2 panels for each drop line, Maximum sixty-four IP connections. 100BaseT (CAT 5) 328 Ft.
NStar Server 100BaseT (CAT 5) 328 Ft. RS-485 Cable RS-485 NS2 Panel NS2 Panel. Honeywell Access Systems NS2 Configuration Guide LANSRLU1 Connection Thirty-one panels for each drop line, Maximum sixty-four IP connections. 100BaseT (CAT 5) 328 Ft.
NStar Server 100BaseT (CAT 5) 328 Ft. RS-485 Cable RS-485 NS2 Panel NS2 Panel DIP Switch Settings. NS2 Configuration Guide Honeywell Access Systems Lease Line Modem Connection Thirty-one NS2 panels for each drop line.
Straight Thru Cable (9-25 Pin) Female 9 Pin Male 25 Pin (RX) (RX) (TX) (TX) (Comm) 5 7 (Comm) M-9600-LO COM Port RS-232 (50 Ft.). Honeywell Access Systems NS2 Configuration Guide RS-485 Short Haul Modem Connection Thirty-one NS2 panels for each drop line. RS232 Cable MODEM (Straight) (DB-9) (Null) RS-232, 50 Ft. 2 (TX) 2 (RX) 2 TX 3 (RX) 3 (TX) 3 RX.
NS2 Configuration Guide Honeywell Access Systems RS-232 Short Haul Modem Connection One NS2 panel for each loop. RS232 Cable MODEM (Straight) (Null) (DB-9) RS-232, 50 Ft. 2 (TX) 2 (RX) 2 TX 3 (RX) 3 (TX) 3 RX 7 (GND).
Honeywell Access Systems NS2 Configuration Guide M-9600 Dial-up Modem, RS-485 Connection Thirty-one NS2 panels for each drop line. M-9600-2 Straight Thru Cable (9-25 Pin) Female 9 Pin Male 25 Pin (RX) (RX) NStar Server Analog Phone Line (TX) (TX) (Comm) 5. NS2 Configuration Guide Honeywell Access Systems M-56K Dial-up Modem, RS-485 Connection Thirty-one NS2 panels for each drop line. M-56K FAX/MODEM COM Port Straight Thru Cable Local DIP Switch Settings (1, 3, 5, 8 ON) (2, 4, 6, 7 OFF) Female 9 Pin. Honeywell Access Systems NS2 Configuration Guide Fiber Converter to RS-485 Connection Thirty-one NS2 panels for each drop line. RS-485 Refer to 485-PCI/NS2 Panel (4000 Ft. Max.) Connection Detail diagram.
COM Port RS-232 (50 Ft. Max.) N-485-PCI-2 NStar Server Panel FC485. NS2 Configuration Guide Honeywell Access Systems 485-PCI/NS2 Panel Connection Detail 485 Interface Connection Types DIP Switch Settings RS-485 NS2 Panel S1: ON N-485-PCI-2 COM Port S2: ON N-485-HUB-2 M-56K Modem S3: ON N-485-PCI-2L LANSRL100 or LANSRLU1 S4: ON S5: ON. Honeywell Access Systems NS2 Configuration Guide Frequently Asked Questions Question: What pre-packaged kits are available? Honeywell Access has made the NS2 available in pre-packaged kits to make ordering easier. Kit Description Contents NSSKR Starter kit with readers.
Software, panel, 2 readers, accessories. How do I upgrade the NS2 Firmware? The NS2 panel uses FLASH memory. This means never having to replace a firmware chip to take advantage of system upgrades or new features.
See Honeywell Access Systems website (www.honey- wellaccess.com) for further details and downloads.